Hastelloy C276 Sintered Filters
For the duties 316L walks away from: HCl, wet chlorine, hypochlorite, mixed acid service
Overview
Before asking the price, place the duty. C276 runs 4-8× the price of 316L; the wrong direction is not an overspend, it is spending at all.
C276 is required when: hydrochloric acid (any concentration, ambient), wet chlorine gas or chlorine water (dry chlorine is the exception - 316L handles it), hypochlorite solutions (bleach, sodium hypochlorite), mixed acids (nitric + hydrochloric, sulfuric + hydrochloric), chlorinated organic media. The common thread: chloride ions with water present.
316L is enough when: neutral salt solutions at moderate concentration and temperature, dilute sulfuric (<5%), phosphoric and acetic acid, short-term flushed seawater exposure, sanitary food/pharma media.
Neither works when: concentrated nitric or fuming sulfuric (strong oxidizing - molybdenum actually hurts here), hot fluoride media (HF at any concentration needs case review), molten alkali metals. We will decline those orders rather than sell a failure.
One-line rule: chloride ions and water together, above 60 °C or below pH 4 → C276. Chloride without water (dry chlorine) → 316L. Fluoride present → neither; call us.
Specifications
| Grade | C276 (UNS N10276): Ni bal., Mo 15-17%, Cr 14.5-16.5%, W 3-4.5%, Fe 4-7% |
|---|---|
| Diameter | φ20 - 200 mm |
| Length | Up to 1500 mm, to drawing |
| Rating | 0.2 - 100 μm |
| Continuous temperature | ≤600 °C (reducing; oxidizing discussed separately) |
| Fittings | Thread, flange, Tri-Clamp, 222/226, plain weld end |
| Documents | Material certificate + spectrometric analysis per batch |
FAQ
- Wet vs dry chlorine - why does it matter?
- Wet chlorine attacks 316L aggressively while dry chlorine is comparatively benign - water is the trigger, which is why C276 is specified for wet service.
- Plate versions available?
- Yes - C276 sintered plates share the same powder and furnace line.
- Can we verify the alloy?
- Spectrometric (PMI) analysis report ships with the batch; third-party re-test welcome.
Send your medium, temperature, pressure and target rating to [email protected] - drawings and annual quantities welcome. Free samples; material certificate and measured bubble-point / permeability data with every batch. Lead time 7-15 days standard, 10-20 for composite builds.
Email [email protected]